MEDIUM VOLTAGE SWITCHBOARD

Schneider - PIX 24 MV Switchboard

Hawee - HPM MV Switchboard

  • Protection against internal arc according to the latest IAC test AFLR, 40kA, 1s.
  • Quick arc flash detection with our sensors to limit the impact of an internal arc.
  • Thermal monitoring with our TH110 sensors and environmental monitoring with our CL110 sensors, for real time online informatiton about health status, available 24/7.
  • PIX 24 is compliant with IEC standards for metal clad switchgear and tested according to
    IEC 62271-200:2011.
  • Front and rear cable access for flexible installations.
  • Protection against internal arc according to the latest IAC test AFLR, 40kA, 1s.
  • Quick arc flash detection with our sensors to limit the impact of an internal arc.
  • Thermal monitoring with our TH110 sensors and environmental monitoring with our CL110 sensors, for real time online informatiton about health status, available 24/7.
  • HPM is compliant with IEC standards for metal clad switchgear and tested according to IEC 62271-200:2011.
  • Front and rear cable access for flexible installations.
LOW VOLTAGE SWITCHBOARD​

Schneider - BlokSeT LV Switchboard

Siemens – Sivacon S8 LV Switchboard

  • Designed and manufactured in accordance with IEC 61439-1.2.
  • Certified by ASTA, ASEFA and Dekra, tested by accredited laboratories.
  • Greater reliability, flexibility and intelligence.
  • High-grade safety BlokSeT with internal arc prevention according to IEC 61641.
  • Active arc flash detection to maximize human safety and minimize damage to installations.
  • Safety even in chemical, dusty and humid environments.
  • Safety even in seismic environments.
  • Designed and manufactured in accordance with IEC 61439-1.2.
  • Certified by ASTA, ASEFA and Dekra, tested by accredited laboratories.
  • Flexibility and intelligence for greater reliability.
  • Superior safety with internal arc prevention according to IEC 61641.
  • Active arc flash detection to maximize human safety and minimize installation damage.
  • Safety even in chemical, dusty and humid environments.
  • Safety even in seismic environments.

Hawee - MSB LV Switchboard

Hawee - DB LV Switchboard

  • Designed and manufactured in accordance with IEC 61439-1.2.
  • Full range design from 630A to 6300A.
  • Certified by ASTA to 4000A, 85kA/s.
  • Certified according to IEC60439-1 by the quality standard development research institute.
  • Designed and manufactured in accordance with IEC 61439-1.2.
  • Full range design from 63A to 1600A, motor up to 250kW.
  • Certified by Quatest-1 according to IEC61439-1 and IEC60529.
  • Certified according to IEC60439-1 by the quality standard development research institute.