MEDIUM VOLTAGE CABLE ( 3 CORES )

CXV/S – AXV/S 3.6/6 (7.2)kV

CXV/DATA – AXV/DATA 3.6/6 (7.2)kV

CXV/AWA – AXV/AWA 3.6/6 (7.2)kV

CXV/DATA – AXV/DATA – 3 Cores 12/20 (24)kV or 12.7/22 (24)kV

CXV/SWA – AXV/SWA – 3 Cores

  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (2 aluminum strips)
  • Sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (aluminum wire)
  • Sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (2 aluminum strips)
  • sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (steel wire)
  • Sheathed

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 6/10(12)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)

CXV/S – AXV/S – 3 Cores 6/10 (12)kV

CXV/SEhh/DSTA – 3 Cores 12/20 (24)kV or 12.7/22 (24)kV

CXV/SEhh/SWA 12/20 (24)kV or 12.7/22 (24)kV

CXV/S – AXV/S 18/30 (36)kV

CXV/SWA – AXV/SWA – 3 Cores 18/30(36)kV

  • Power cable
  • 3 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 3 cores
  • Copper core
  • Metal screen including copper wire and tape
  • Armored (2 steel tapes)
  • Sheathed
  • Power cable
  • 3 cores
  • Copper core
  • Metal screen including copper wire and tape
  • Armored (steel wire)
  • Sheathed
  • Power cable
  • 3 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (steel wire)
  • Sheathed

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(Um): 6/10(12)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage Uo/U(Um): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 18/30(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 18/30(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)

CXV/SWA – AXV/SWA – 3 Cores 19/33(36)kV

CXV/DSTA – AXV/DSTA – 3 Cores 18/30(36)kV

CXV/S – AXV/S 12/20 (24)kV or 12.7/22 (24)kV

  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (steel wire)
  • Sheathed
  • Power cable
  • 3 cores
  • Copper or aluminum core
  • Armored (2 steel tapes)
  • Sheathed
  • Power cable
  • 3 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(U m ): 19/33(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 18/30(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)