MEDIUM VOLTAGE CABLE ( 1 CORE )

CXV/S – AXV/S 3.6/6 (7.2)kV

CXV/DATA – AXV/DATA 3.6/6 (7.2)kV

CXV/AWA – AXV/AWA 3.6/6 (7.2)kV

CXV/S – AXV/S 6/10 (12)kV

CXV/AWA – AXV/AWA 6/10 (12)kV

  • Power cable
  • 1 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 1 core, copper or aluminum core
  • Armored (2 aluminum strips)
  • Sheathed
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Armored (aluminum wire)
  • Sheathed
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Armored (aluminum wire)
  • Sheathed

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable
  • Rated voltage U o /U(U m ): 3.6/6(7.2)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 6/10(12)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 6/10(12)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)

CXV/S – AXV/S 18/30 (36)kV

CXV/AWA – AXV/AWA 18/30 (36)kV

ACX-WBS 12/20 (24)kV or 12.7/22 (24)kV

ACX-WB 12/20 (24)kV or 12.7/22 (24)kV

ACXV-WBS 12/20 (24)kV or 12.7/22 (24)kV

  • Power cable
  • 1 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Armored (aluminum wire)
  • Sheathed
  • Power cable
  • 1 core
  • Aluminum core Steel core
  • Waterproof
  • Conductor screen
  • XLPE insulation
  • Power cable
  • 1 core
  • Aluminum core steel core
  • Waterproof
  • XLPE insulation
  • Power cable
  • 1 core
  • Aluminum core
  • Steel core with waterproofing
  • Conductor screen
  • XLPE insulation
  • PVC sheath

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(U m ): 18/30(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 18/30(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)

ACXH 12/20 (24)kV or 12.7/22 (24)kV

AX-WBS 12/20 (24)kV or 12.7/22 (24)kV

AXV 12/20 (24)kV or 12.7/22 (24)kV

CX-WBS 12/20 (24)kV or 12.7/22 (24)kV

CXHS 12/20(24)kV or 12.7/22(24)kV

  • Power cable
  • 1 core
  • Aluminum core steel core
  • XLPE insulation
  • HDPE sheath
  • Power cable
  • 1 core
  • Aluminum core with waterproofing
  • Conductor shield
  • XLPE insulation
  • Power cable
  • 1 core
  • Aluminum core
  • XLPE insulation
  • PVC sheet
  • Power cable
  • 1 core
  • Copper core with waterproofing
  • Conductor shield
  • XLPE insulation
  • Power cable
  • 1 core
  • Copper core
  • Conductor screen
  • XLPE insulation
  • HDPE sheath

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage Uo/U(Um): 12/20(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)

CXH 12/20(24)kV or 12.7/22(24)kV

CXV/AWA – AXV/AWA 19/33(36)kV

CXV/SEhh/DATA-W 12/20 (24)kV or 12.7/22 (24)kV

CXV/DATA – AXV/DATA 12/20 (24)kV or 12.7/22 (24)kV

CXV/S – AXV/S 12/20 (24)kV or 12.7/22 (24)kV

  • Power cable
  • 1 core
  • Copper core
  • XLPE insulation
  • HDPE sheath
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Armored (aluminum wire)
  • Sheathed
  • Power cable
  • 1 core
  • Copper core
  • Waterproof
  • Armored (2 aluminum strips)
  • With sheath
  • Power cable
  • 1 core, copper or aluminum core
  • Armored (2 aluminum strips)
  • Sheathed
  • Power cable
  • 1 core
  • Copper or aluminum core
  • Unarmored
  • Sheathed

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

Cable Characteristics:

  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 19/33(36)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 12 x D (D: outer diameter of cable)
  • Rated voltage U o /U(U m ): 12/20(24)kV or 12.7/22(24)kV
  • Maximum conductor temperature in normal operation: 90 o C
  • Minimum bend radius: 8 x D (D: outer diameter of cable)